SetFavorite  | ◎ SetHome  | ◎ Contact    
Xuzhou Nendar Combustion Control Engineering Co., Ltd
http://www.nendar.com
Phone:0516-83899666
postcode:221008
E-mail:xznengda@126.com
Address:Hardware district 1 11,National University Science Park of China University of Mining and Technology,Xuzhou,Jiangsu,China

NDSY-2 Automated Measuring Systems

1.Overview:

NDSY-2 high-temperature combustion pressure valve leakage test platform for the automatic measurement system test piece (with a pressure valve) internal and external leakage during the combustion.

 

2.functions

- Automatic transmission features artifacts

Workpiece burn outdoors, connect the pressure pipe by hand and fixed on the table support. When ready, the system will automatically delivered to the combustion chamber of its predetermined position; After the measurement is completed, the system then automatically delivered to their burning outdoors.

 

- Automatic compression artifacts, pressure relief function

According to a preset pressure parameters, the system automatically start and stop the pump, automatic compression; After exiting the combustion chamber, the system then automatically open the drain valve decompression.

 

- Automatic retreat function burner

The default size of the burner according to the workpiece, the number of inputs automatically selected burner automatically advancing to the position of optimum combustion, the flame automatically select the number of inputs of the respective burner, flame guarantee the accuracy of the workpiece surrounding the periphery of the workpiece does not occur beyond excess flame ; After burning is complete, and then automatically return to its original position.

 

- Automatic combustion burner on and off function

As the temperature of the workpiece changes, the burner according to the preset workpiece temperature, and automatically turns off the combustion, the fuel flow rate is automatically adjusted to achieve the purpose of regulating the flame length and width.

 

- Automatic ignition burner function

When the need to burn the burner, automatic ignition.

 

- Fire protection

Automatic detection of each main burner flame, automatically cut off the fuel when the main flame is extinguished.

 

- Automatic measurement

Automatically measuring the amount of leakage of the workpiece at high pressure conditions, the automatic measurement of the flame temperature of the main burner and the surface temperature, the internal pressure.

 

- Automatic cooling

After the measurement is completed, the system automatically transport the workpiece to burn outdoors, and automatically spray cooling, when the temperature reaches a preset value, automatically stops cooling.

 

- Automatic data acquisition and storage

The system automatically collect artifacts pressure, temperature, leakage and measurement of time, complete control of the user interface, status display, report, workpiece temperature - real-time, historical curve, the flame temperature - real-time, historical curve, pressure - time real-time, historical curve, and printing and storage.

 

- Manual operation