- Flame Detector System
- Furnace Safety Supervision System(FSSS)
- Ignition Control System
- The Ignition And Combustion Equipment
- Energy-saving Combustion System
- Combustion Test Bench
- PLC Programmed Control System
- Industrial Television Monitoring System
- NDTV-1 Endoscopic Type Hig…
- NDTV-2 Drum Water Level TV…
- NDTV-3 Industrial TV Syste…
- Flare System
- Intelligent Online Soot Blowing System
- Acoustic Gas Temperature Measurement System(SEI)
- Compressor Optimization Control System(CCC)
http://www.nendar.com
Phone:0516-83899666
postcode:221008
E-mail:xznengda@126.com
Address:Hardware district 1 11,National University Science Park of China University of Mining and Technology,Xuzhou,Jiangsu,China
NDTV-1 Endoscopic Type High Temperature Furnace Flame Television Monitoring System
Endoscopic type high temperature furnace flame NDTV - 1 TV system is applicable to coal, oil, gas and so on all kinds of boiler and furnace chamber of a stove or furnace flame monitoring. The combustion status of furnace directly displayed on the monitor, it has convenience of operation personnel to observe, timely adjustment of combustion, effectively prevent boiler explosion. The hearth of this system adopted high temperature resistant sapphire camera probe and special ceramic materials, can truly observe the combustion chamber of a stove or furnace flame. The whole equipment design, small size, large viewing Angle, less gas, strong anti-interference ability, high temperature resistance, corrosion resistance, the image is clear.
2.The main technical parameters
2.1 Probe parameters
item parameter operating temperature ≤1800℃ field angle 90°、70°
2.2 Camera parameters
item parameter power 220V 50Hz Scanning area 4.8×3.6mm Video output 1.0v[p-p]PAL Composite 75Ω/BNC Joints Analysis of the level of force as( line) 480(Level Center) SNR(dB) 50 Minimum illumination(1ux) 0.9(F0.75)
2.3 Parameter Monitor (monitor size could be selected according to user requirements)
item parameter Power AC220-240V Video input 1.0V[p-p] Composite /75Ω Standard definition(line) 500(Level Center)
2.4 Electric propulsion parameters
item |
parameter |
Working trip(mm) |
600 |
Travel Time( s) |
6 |
Power |
AC380V 50Hz 1.2A |
Appearance size (mm) |
1350×140×120 |
2.5 Cooling and wind parameters Purge
item parameter Type Instruments used compressed air or air supply, wind flame detector Air pressure ≥0.0045Mpa Flow ≥60M3/h Air temperature ≤40℃ Dust particle size ≤5um
2.6 Electric parameters control cabinet
item |
parameter |
Power |
AC380V 50Hz 5A |
Dimensions (width x depth x high)(mm) |
450×600×300 |
2.7 Controller parameters
item parameter Power AC220V 50Hz 2A Dimensions (width x depth x high)( mm) 160×80×300
2.8 Pressure switch parameters
item |
parameter |
Setting the scope of regulation |
0.01-0.25Mpa(or 0.00-0.01Mpa) |
The maximum allowable pressure |
1Mpa(or 0.05Mpa) |
2.9 Environmental Conditions
-Endoscopic camera probe maximum operating ambient temperature: 1800 ℃
-Other parts of the operating temperature: -25 ℃~ +70 ℃, relative humidity: <90% RH