SetFavorite  | ◎ SetHome  | ◎ Contact    

NDTV-1 Endoscopic Type High Temperature Furnace Flame Television Monitoring System

 


1.summarize

Endoscopic type high temperature furnace flame NDTV - 1 TV system is applicable to coal, oil, gas and so on all kinds of boiler and furnace chamber of a stove or furnace flame monitoring. The combustion status of furnace directly displayed on the monitor, it has convenience of operation personnel to observe, timely adjustment of combustion, effectively prevent boiler explosion. The hearth of this system adopted high temperature resistant sapphire camera probe and special ceramic materials, can truly observe the combustion chamber of a stove or furnace flame. The whole equipment design, small size, large viewing Angle, less gas, strong anti-interference ability, high temperature resistance, corrosion resistance, the image is clear.

 

2.The main technical parameters

2.1 Probe parameters

item

parameter

operating temperature

≤1800

field angle

90°70°

 

2.2 Camera parameters

item

parameter

power

220V  50Hz

Scanning area

4.8×3.6mm

Video output

1.0v[p-p]PAL Composite 75Ω/BNC Joints

Analysis of the level of  force as( line)

480Level Center

SNR(dB)

50

Minimum illumination(1ux)

0.9F0.75

 

2.3 Parameter Monitor (monitor size could be selected according to user requirements)

item

parameter

Power

AC220-240V

Video input

1.0V[p-p] Composite /75Ω

Standard definition(line)

500Level Center

 

2.4 Electric propulsion parameters

item

parameter

Working trip(mm)

600

Travel Time( s)

6

Power  

AC380V     50Hz      1.2A

Appearance size (mm)

1350×140×120

 

2.5 Cooling and wind parameters Purge

item

parameter

Type

Instruments used compressed air or air supply, wind flame detector

Air pressure

≥0.0045Mpa

Flow

≥60M3/h

Air temperature

≤40

Dust particle size

≤5um

 

2.6 Electric parameters control cabinet

item

parameter

Power

AC380V    50Hz    5A

Dimensions (width x depth x high)(mm)

450×600×300

 

2.7 Controller parameters

item

parameter

Power

AC220V    50Hz    2A

Dimensions (width x depth x high)( mm)

160×80×300

 

2.8 Pressure switch parameters

item

parameter

Setting the scope of regulation

0.01-0.25Mpaor 0.00-0.01Mpa

The maximum allowable pressure

1Mpaor 0.05Mpa

 

2.9 Environmental Conditions  

-Endoscopic camera probe maximum operating ambient temperature: 1800

-Other parts of the operating temperature: -25 ~ +70 , relative humidity: <90% RH